דטישרותי אופטיקה בע״מ
ביתמכשורלייזרים רשתיתLumeProbe
LumeProbe
לייזרים רשתית

LumeProbe

בקשת הצעת מחיר

\n

\n

\n

\n

\n

\n

LumeProbe

\n

\n

\n

\n

\n

Endo-Photocoagulation Laser Probes

\n

\n

\n

\n

\n \nAt Lumenis, we truly understand retinal photocoagulation technology; that is after all only one of the privileges reserved for the company that pioneered the first argon laser photocoagulator for ophthalmology. \n \nOur newest line of premium ophthalmic endo-photocoagulation laser probes was designed with the retina specialist in mind. Advanced manufacturing practices, unique fiber polishing techniques and uncompromising quality assurance methodologies deliver product performance & reliability second to none. \n \nFurthermore, elements of ergonomics incorporated into the design of the LumeProbe hand-piece provide you with proprietary advantages of comfortable grip and easier guidance towards the treatment site throughout the laser procedure. \n \n

\n

\n

\n

\n

\n

\n

\n

\n

\n

\n

\n

\n

LumeProbe Benefits & Features

\n

\n

\n

\n

\n \nConcentric Laser Burns \n \nAdvanced optics and laser delivery technology, coupled with sophisticated fiber polishing techniques, deliver concentric laser burns and uniform energy distribution across the entire laser spot area, for more precise and safer treatment. The result is a homogenous laser spot with evenly distributed power across the entire spot, eliminating the potential risk for the formation \n \n

\n

\n
\n

\n

\n \nOptimized Energy Transmission \n \nEach LumeProbe was designed to be connected directly to a compatible laser port. In light of that, the LumeProbes do not require special adapters when being used with any SMA 905- or 906 connector-based devices, thereby eliminating laser transmission inefficiencies. Connecting the LumeProbe directly into the laser port without the need for an adapter ensures enhanced laser transmission efficiency of more than 8% compared to using a laser probe which requires an adapter. \n \nEffect of Connecting Adapter on Transmmission Efficiency \n

\n

\n


\n

\n

\n

\n

\n

\n

\n

\n

\n

\n

\n \nEnhanced Safety \n \nThe ability to connect the LumeProbe directly into the laser console also delivers two key safety elements during each and every procedure: \n \n

\n

\n

\n

\n

\n

\n

\n

\n

\n

\n

\n \n  \n

Laser parameters and power calibration remain valid throughout the procedure.

\n  \n

Optimized energy transmission ensures the integrity of the probe’s protective polymer coating along with the adhesive bonding between the laser optical fiber and the hand-piece.

\n

\n

\n

\n

\n

\n
\n

\n

\n \nReliability & Predictability \n \nAdvanced laser probes manufacturing techniques and sophisticated quality-assurance methodologies which are based on over 25 years of experience provide you with product reliability and predictability you can count on from case to case. The LumeProbe product family was designed to deliver the results you come to rely on and expect from a premium product in order to achieve optimal clinical outcomes time and again. \n \n

\n

\n
\n

\n

\n \nMeeting your needs \n \nThe LumeProbe product family consists of comprehensive and wide selection of ophthalmic endophotocoagulation probes to meet every clinical need and indication. These include standard, straight, curved, aspirating, illuminating and stepped in 20, 23 and 25 gauge sizes, among others. \n \n

\n \n \n \n \n \n \n \n \n \n \n \n \n \n \n \n \n \n \n \n \n \n \n \n \n \n \n \n \n \n

TypeFeatures and Benefits

Straight \n(laser probe)

\n

  • \n
  • Basic endophotocoagulator for non-peripheral retinal locations
  • \n
  • Most efficient delivery of thermal energy
  • \n
  • Ease of entry through small gauge cannulas
  • \n

\n

Curved & Stepped \n(versatile)

\n

  • \n
  • Tapered curved for ease of entry through small gauge cannulas
  • \n
  • Unique curve for efficient spot placement at far peripheral locations
  • \n
  • Versatile for central or peripheral use
  • \n

\n

Illuminated \n(enhanced visualization and multifunctional)

\n

  • \n
  • Provides direct illumination for improved visualization of retinal tears in the far periphery
  • \n
  • Allows direct visualization from a single probe during scleral depression
  • \n

\n

Aspirating \n(multifunctional)

\n

  • \n
  • A dual-purpose instrument provides the surgeon with higher efficiency during the procedure
  • \n
  • Aspiration capabilities allow the surgeon to manage retinal fluids more efficiently
  • \n
  • Both passive or active aspiration capabilities provide the surgeon with more options
  • \n

\n

\n

\n

\n

\n \n23 & 25 gauge Advantage \n \nThe LumeProbe 23 and 25 gauge selection provides you with the benefits of a less invasive procedure without compromising on the rigidity and stability of the probe during the operation. \n \nBased on over 25 years of laser probes manufacturing expertise, the LumeProbe product family was designed to deliver laser energy in the safest and most efficient manner, guaranteeing optimal clinical outcome for all relevant viteroretinal indications. \n \n

\n

\n

\n
\n

\n

\n

\n

\n

\n

\n

\n

\n

\n

\n

\n

\n

\n

מכשור קשור

אולי יעניין אתכם

Smart Selecta Trio
Smart Selecta Trio
<p dir="ltr" style="text-align: left;">Selective Laser Trabeculoplasty (SLT) for Glaucoma treatment</p>
Array LaserLink
Array LaserLink
<div class="wpb_text_column wpb_content_element vc_custom_1532606340992 ophthalmology-color"> \n<div class="wpb_wrapper"> \n<p dir="ltr" style="text-align: left;">Array LaserLink<sup>TM</sup></p> \n \n</div> \n</div> \n<div class="wpb_text_column wpb_content_element vc_custom_1532606357774 ophthalmology-color" dir="ltr" style="text-align: left;"> \n<div class="wpb_wrapper"> \n \nPattern Scanning Laser Technology \n \n</div> \n</div>
Smart 532
Smart 532
<div class="wpb_text_column wpb_content_element vc_custom_1532770284201 ophthalmology-color"> \n<div class="wpb_wrapper"> \n<p dir="ltr" style="text-align: left;">Smart532</p> \n \n</div> \n</div> \n<div class="wpb_text_column wpb_content_element vc_custom_1532770024335 ophthalmology-color" dir="ltr" style="text-align: left;"> \n<div class="wpb_wrapper"> \n \nThe SmartPulse™ of Retinal Care \n \n</div> \n</div>
VisionOne
VisionOne
<div class="wpb_text_column wpb_content_element vc_custom_1605092227887 ophthalmology-color"> \n<div class="wpb_wrapper"> \n<p dir="ltr" style="text-align: left;">Vision One – Retinopathy Laser</p> \n \n</div> \n</div> \n<div class="wpb_text_column wpb_content_element vc_custom_1605092248230 ophthalmology-color" dir="ltr" style="text-align: left;"> \n<div class="wpb_wrapper"> \n \nMulti-Wavelength Photocoagulation System \n \n</div> \n</div>

מעוניינים בLumeProbe?

נשמח לתאם הדגמה, לייעץ ולהתאים עבורכם את הפתרון הנכון.