דטישרותי אופטיקה בע״מ
ביתמכשורלייזרים רשתיתVisionOne
VisionOne
לייזרים רשתית

VisionOne

<div class="wpb_text_column wpb_content_element vc_custom_1605092227887 ophthalmology-color"> \n<div class="wpb_wrapper"> \n<p dir="ltr" style="text-align: left;">Vision One – Retinopathy Laser</p> \n \n</div> \n</div> \n<div class="wpb_text_column wpb_content_element vc_custom_1605092248230 ophthalmology-color" dir="ltr" style="text-align: left;"> \n<div class="wpb_wrapper"> \n \nMulti-Wavelength Photocoagulation System \n \n</div> \n</div>

בקשת הצעת מחיר

\n

\n

Vision One – Retinopathy Laser

\n

\n

\n

\n

\n

Multi-Wavelength Photocoagulation System

\n

\n

\n

\n

\n

Product Highlights

\n

\n

\n

\n

Modular and upgradable – Ability to upgrade the system at any time by a adding wavelengths as a scanner \nUser friendly design – Touch screen and remote keypad, Dual Port for efficient setup of alternate delivery devices, advance memory settings \nSureSpot™ Optics Technology  – Sharply defined and evenly distributed power on the retina

\n  \n

\n

\n \n Red (659 nm) \n \n

\n

\n

\n

\n \nRed laser light offers excellent penetration through hemoglobin, making it the wavelength of choice in situations where it is necessary to penetrate through preretinal, subretinal or intraretinal hemorrhage. \n \nIt is also the optimal wavelength for achieving deeper penetration into the choroid to treat choroidal melanomas or other deep pigmented lesions. \n \nIt is also the preferred wavelength for treating infant eyes with ROP because it penetrates through the tunica vasculosa lentis, the vascular network surrounding the lens. Absorption by those vessels is associated with higher risk for cataract formation. \n \n

\n

\n

\n \n  Yellow (577 nm) \n \n

\n

\n

\n

\n \nYellow Laser light offers the clinician high absorption in hemoglobin and negligible absorption in macular Xanthophyll. \n \nIn addition to easily penetrating through nuclear sclerotic cataracts, the yellow wavelength is desirable when it is necessary to penetrate through fluid, such as when treating a retinal detachment or tear. It also penetrates mild pigmentary disturbances and so is well suited for conditions where the target lies in a region of previous photocoagulation treatment. One of the main advantages of yellow laser light stems from the fact that it approximates the peak absorption of hemoglobin, xanthophyll in the neurosensory retina. Therefore, it is recommended for focally treating extrafoveal microaneurysms or other vascular lesions in the macular region that may cause macular edema. \n \nIn addition, yellow laser produces significantly less light scatter, allowing for more efficient treatment and requiring lower energy levels to achieve desirable clinical outcome; this creates significantly less discomfort for the patient during and following the laser procedure. \n \n

\n

\n

\n \n  Green (532 nm) \n \n

\n

\n

\n

\n \nGreen laser light is a clinically-proven wavelength that is excellent at targeting the melanin-containing retinal pigment epithelium (RPE), through clear ocular media. It is well suited for a variety of retinal treatments in which melanin is the target chromophore, such as pan-retinal photocoagulation (PRP). \n \n

\n

\n

\n

\n

\n

\n

\n

\n

\n

\n

\n

System Benefits

\n

\n

\n

\n

\n

Advanced Control

\n

\n

\n

\n

\n \nVoice Confirmation – The Vision One is equipped with a unique voice confirmation feature, which allows the user to change any of the key parameters, while receiving a vocal confirmation of the dialed choice. This feature allows the operator to adjust parameters also during treatment, without having to shift view from the treatment site to the unit’s control panel. \n \n

\n

\n

\n

Dependability you can count on

\n

\n

\n

\n

\n \nCaseSaver Mode – Dependability is of crucial importance in both the OR and Office Setting. \nThe Vision One has laser cavities that work independent of one another. CaseSaver™ Mode: In the unlikely event that one of the laser wavelengths were to become inoperable, the other two* wavelengths will remain operational – allowing you to keep on treating your patients until the unit is promptly serviced by a qualified Lumenis Engineer – part of the largest service network in the industry. \n \n*If unit was purchased with more than one wavelength \n \n

\n

\n

\n

\n

\n

\n

\n

\n

Convenience & Flexibility

\n

\n

\n

\n \n  \n

Dual Fiber Port – Changing delivery devises is fast and easy. The Vision One remembers the settings that were last used with the selected delivery device allowing for a smoother transition.

\n  \n

Memory Settings – The Vision One has five programmable memory setting that can be set to remember the most used treatment parameters.

\n

\n

\n

Intelligent

\n

\n

\n

\n

\n \nSmart™ Fiber Technology – The Vision One features Smart fiber technology that allows the laser system to distinguish an LIO from an endoprobe or LaserLink and will automatically adjust power settings to increase safety parameters. The Lumenis Smart fiber technology also alerts the surgeon and staff if the physician eye safety filter, footswitch and delivery devices are not properly attached to the laser console. \n \n

\n

\n

\n

User-Friendly

\n

\n

\n

\n

\n \nTouch screen & remote keypad – A color touch screen and illuminated remote keypad put all operations literally at your fingertips. Easily adjust parameters or instantly switch between treatment wavelengths. Conveniently position the remote control on either side of the slit lamp, or in a sterile cover for the operating room. \n \nhe Lumenis *PowerEase™ footswitch provides hands-free power adjustment of the laser by toggling left or right within the footswitch housing.The Lumenis *Smart™ footswitch contains an integrated proximity sensor which inserts and removes the physician eye safety filter at the moment you slide your foot in and out of the footswitch housing. * Optional accessories \n \n

\n

\n

\n

ClearView™ Filters

\n

\n

\n

\n

\n \nOptimized view of treatment site – The Lumenis ClearView™ filters’ photopic balanced coating eliminates color distortion of the treatment site while optimizing white light transmission or “brightness” of the physician’s view. \n \n

\n

\n

\n

Versatile

\n

\n

\n

\n

\n \nCompatibility with a wide variety of delivery devices – The Vision One is compatible with a wide variety of accessories and delivery devices – meeting you specific preferences in the outpatient clinic and the OR. Lumenis also developed an integrated laser slit lamp with the retina specialist in mind. \n \nChoose a multicolor Laser Indirect Ophthalmoscope that suits your preferences. Both our Heine and Keeler models are rugged, lightweight and equipped with the most advanced laser delivery technology in the market. The Lumenis family of LaserLinks will transform most commercially available slit lamps into advanced laser delivery devices with superior optics capabilities. \n \n

\n

\n

\n

\n

\n

\n

מכשור קשור

אולי יעניין אתכם

Smart Selecta Trio
Smart Selecta Trio
<p dir="ltr" style="text-align: left;">Selective Laser Trabeculoplasty (SLT) for Glaucoma treatment</p>
Array LaserLink
Array LaserLink
<div class="wpb_text_column wpb_content_element vc_custom_1532606340992 ophthalmology-color"> \n<div class="wpb_wrapper"> \n<p dir="ltr" style="text-align: left;">Array LaserLink<sup>TM</sup></p> \n \n</div> \n</div> \n<div class="wpb_text_column wpb_content_element vc_custom_1532606357774 ophthalmology-color" dir="ltr" style="text-align: left;"> \n<div class="wpb_wrapper"> \n \nPattern Scanning Laser Technology \n \n</div> \n</div>
Smart 532
Smart 532
<div class="wpb_text_column wpb_content_element vc_custom_1532770284201 ophthalmology-color"> \n<div class="wpb_wrapper"> \n<p dir="ltr" style="text-align: left;">Smart532</p> \n \n</div> \n</div> \n<div class="wpb_text_column wpb_content_element vc_custom_1532770024335 ophthalmology-color" dir="ltr" style="text-align: left;"> \n<div class="wpb_wrapper"> \n \nThe SmartPulse™ of Retinal Care \n \n</div> \n</div>
Novus Spectra
Novus Spectra
<div class="wpb_text_column wpb_content_element vc_custom_1532668191374 ophthalmology-color"> \n<div class="wpb_wrapper"> \n<p dir="ltr" style="text-align: left;">Novus Spectra<sup class="h1-title">®</sup></p> \n \n</div> \n</div> \n<div class="wpb_text_column wpb_content_element vc_custom_1537948827891 ophthalmology-color" dir="ltr" style="text-align: left;"> \n<div class="wpb_wrapper"> \n \nHigh-powered photocoagulator \n \n</div> \n</div>

מעוניינים בVisionOne?

נשמח לתאם הדגמה, לייעץ ולהתאים עבורכם את הפתרון הנכון.